SECTION
B
SPECIFICATIONS
Model
No.
GF
3800
Type
of
Appliance
Fan
type
direct
vent
wall
furnace
Input
Rating
Nat.
Gas
38,000
BTU/hour
LP. Gas
34,500 BTU/hour
Output
Rating
Nat.
Gas
30,700 BTU/hour
LP. Gas
27,900
BTU/hour
Efficiency
83%
Electrical
Rating
120V,
60Hz,
Less
than
2
amperes
Power
Consumption
80
Watts
Heated
Air
Delivery
High
388
Cubic
feet/minute
Low
300
Cubic
feet/minute
Flue
Pipe Hole
2.5
inches diameter
Dimensions
Height:
26.6 inches (67.56cm)
Width: 28.7 inches (72.90cm)
Depth:
14.0
inches (35.50
cm)
Weight
82
pounds
Inlet
Gas
Supply Pressure
Nat.
Gas
Max.
10.5
inch
W.C. (267
mmHzO)
Min.
5.1
inch W.C. (130
mmHaO)
LP. Gas
Max.
13.0
inch W.C. (330
mmHzO)
Min.
11.0
inch W.C. (279
mmH
2
O)
Manifold
Test
Pressure
Nat.
Gas 3.4
inch W.C.
(86
mmHzO)
LP. Gas
3.!5inch W.C.
(80mmH2O)
The
minimum
and
maximum
inlet
gas
supply
pressure
are for the
purpose
of
input
adjustment.
The
efficiency rating
of
this appliance
is a
product
of
thermal efficiency rating determined under
continuous
operating
conditions
and was
determined
independently
of any
installed
system.
SPECIAL
FEATURES
AUTOMATIC
IGNITION
MEMORY
BACK
UP: Set
memory
can be
kept
in
case
of
power failure
for up
to30minutes.
DUAL BLOWERS: Separate fans
for
combustion
and
room
air
circulation.
THERMOSTATICALLY
CONTROLLED: Adjusts
to the
desired
room temperature.
BUILT-IN
TIMER: Heater
will
automatically operate
as
programmed
by the
user.
AUTOMATIC
RESET
AFTER
POWER
FAILURE: Heater
will
automatically resume operation
after
power
is
restored.
INDICATOR
LIGHTS:
Easy-to-see
signals show when
heater
is in
operation, when timer
is
activated,
and
when
the
burner
is
operating.
CLEAN OPERATION:
Products
of
combustion
are
vented
outside.
CONSUMES
NO
ROOM AIR:
Air for
combustion
is
drawn
from
outside.
EASY
INSTALLATION: Includes
all
parts required
for
standard
installation.
SAFETY
FEATURES
SAFE RE-LIGHTING: Heater
will
not
restart
until
its
combustion
chamber
has
cooled.
ELECTRICAL PROTECTION: Heater automatically shuts
off
in the
unlikely event
of a
malfunction
in the
electrical
circuitry
or
disruption
of the
power
supply.
NO
EXHAUST
IN
ROOM: Products
of
combustion
are
discharged outdoors.
FLUE PIPE: Outside
air is
drawn through
a
pipe-within-
a-pipe venting system. This process
preheats
combustion
air and
regains
heat
from
exhaust
gases.
/|\
CAUTION:
ALTERNATE POWER SOURCES
The
Monitor
GF3800
may not
operate when powered
by
sources such
as an
auxiliary generator,
UPS
(Uninterrupted Power Source), inverters, etc.
Check
with
your
dealer
for
guidance
on
specific
applications.
Seitenansicht 6